Sign In | Join Free | My ledscreensign.com |
|
Brand Name : Kacise
Model Number : KUS600
Certification : ce,ISO9001
Place of Origin : China (Mainland)
MOQ : 1pcs
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1000 Pieces per Week
Delivery Time : 5work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Product : Ultrasonic Distance Sensor
Detection Range : 300mm~5000mm
Transducer frequency : approx. 220kHz
Output : RS485 + 4-20mA/0-10V
Input power : 3.3V~24V
IP grade : IP68
Material : PVDF
Type : Waterproof
Theory : Ultrasonic Sensor
Warranty : 12 Months
Product name : PVDF 5m Ultrasonic water level meter
1. Parameter
Model: KUS600 | |
Measuring range | 600... 5000 mm. The measure distance can reach 6 meters if the power supply is 24V. |
Blind spot | 600 mm |
Supply voltage | 3.3 ... 24 VDC,ripple 10 %SS |
No-load supply current I0 | ≤ 20 mA active period and ≤0.3mA during sleep time |
Output signal | 0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output. |
Measurement accuracy | ≤1 %F.S. |
Temperature compensation | Yes |
Ranging resolution | 0.1mm; |
Working conditions
Working temperature | -40…85℃(233...358K) |
Storage temperature | -40…85℃(233...358K) |
Other instructions
Electrical connection | 5-core cable (analog output), 6-core cable (switch output); |
Protection class | IP68 |
shell material | PVC /PVDF/PTFE/ABS |
Cable color | Pin | Description | Note |
Red | 1 | Power supply |
|
Black | 2 | GND |
|
Yellow | 3 | Analogue output | The 600B will work in mode 1 or 0 cannot work in power save mode, if the 4-20mA, 0-3.3V 0-5V analogue output used. |
Blue | 4 | RS485A+ | TTL-TXD for ttl output signal |
Green | 5 | RS485B- | TTL-RXD for ttl output signal |
For switch output
Cable color | Pin | Description | Note |
Red | 1 | Power supply |
|
Black | 2 | GND |
|
Yellow | 3 | Switch output | Load current 1A@60V |
White | 4 | Switch output | |
Brown | 5 | RS485A+ | TTL-TXD for ttl output signal |
Green | 6 | RS485B- | TTL-RXD for ttl output signal |
Unit in the diagram is mm
4. Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
5. Ordering information
KUS | Body size | OUTPUT | Max range | Description |
| 600 |
| ||
| Customized | Customized | ||
|
| SW | Switch Output (online configurable for NPN or PNP) | |
|
| mA | 3 wire 4-20mA output | |
|
| 10V | Output is Vout 0-10V | |
|
| 5V | Output is Vout 0-5V The power supply range is 5.0 at least | |
|
| 3.3V | Output is Vout 0-3.3V The power supply range is 3.3 at least | |
|
| RS485 | Output is RS485 | |
|
| TTL | UART TTL output | |
|
|
| XXX mm | Xxx mm is the maxim range can be detected, the default length is 1 meter |
KUS | 600 | RS485 | 5000mm |
6. Packing and shipping
![]() |
6V Ultrasonic Water Tank Level Meter RS485 5m High Accuracy Liquide Level Measure Images |