Sign In | Join Free | My ledscreensign.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

7 Years

Home > Water Quality Sensor >

Online Turbidity Water Clarity Sensor 20m Depth KTU310

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Online Turbidity Water Clarity Sensor 20m Depth KTU310

  • 1
  • 2

Brand Name : kacise

Model Number : KTU310

Certification : CE

Place of Origin : CHINA

MOQ : 0-100

Price : $0-$2000

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100

Delivery Time : 3-10days

Packaging Details : Common package or custom package

Measuring principle : Scattering method

Range : 0 ~ 100 NTU

Resolution : 0.1 NTU, 0.1 °C

Precision : ± 3% or ± 2 NTU ± 0.5 °C

Calibration mode : Two-point calibration

Temperature compensation : Automatic temperature compensation (PT1000)

Contact Now

Online Turbidity Water Clarity Sensor 20m Depth KTU310

1.Principle

The KTU310 integrated online turbidimeter is designed and made by the principle of scattering light turbidimeter. When a beam of light enters a water sample, the light is scattered by the turbidity material in the water sample. The turbidity in the water sample can be calculated by measuring the intensity of the scattered light in the vertical direction of the incident light and comparing it with the internal calibration value, the final value is output after linearization.

2.Feature

90 ° angle scattering principle, built-in temperature sensor

Support RS-485, Modbus/RTU protocol

Fiber structure, the strong anti-interference ability of external light

The infrared LED light source, high stability

IP68, shield, water depth, 20 meters

Convenient, fast, stable, and easy to maintain

3.Technical Specifications

Model number KTU310
Measuring principle Scattering method
Range 0 ~ 100 NTU
Resolution 0.1 NTU, 0.1 °C
Precision

± 3% or ± 2 NTU

± 0.5 °C

Calibration mode Two-point calibration
Temperature compensation Automatic temperature compensation (PT1000)
Output mode RS-485(Modbus/RTU)
Working conditions 0ー50 °C, < 0.2 mpa
Storage temperature - 5 ~ 65 °C
Installation mode Immersion mounting, 3/4 NPT thread
Power consumption < 0.05 W
Power supply 12 ~ 24 VDC ± 10%
Protection level IP68

4.Dimensional Drawing

Online Turbidity Water Clarity Sensor 20m Depth KTU310

Tips: Orion Method AQ4500

The Orion Method AQ4500 was developed by Thermo Scientific and is based on the use of their turbidity meter, Thermo Orion AQUAfast Turbidimeter Model AQ4500. This method follows all the requirements of EPA Method 180.1 except for the specified light source. This method still requires a 90-degree photodetector with a spectral response between 400 nm and 600 nm, and incident and scattered light cannot travel further than 10 cm combined.

Online Turbidity Water Clarity Sensor 20m Depth KTU310

The spectral output of a coated blue LED is like that of a tungsten lamp.

Instead of using a polychromatic tungsten lamp as a light source, the Orion method AQ4500 uses a “white” LED. To achieve a broadband output with a typically narrow band LED, this method uses a phosphorus coated blue LED. This expands the spectral output from the blue 450 nm wavelength to a wide spectrum response like a tungsten source/cadmium sulfide detector combination.

Furthermore, the use of an LED light source allows for rapid pulsing operation. By pulsing the light, this method permits synchronous detection 40. Synchronous detection means that any stray light or electronic-induced errors can be reduced and nearly cancelled out. The Orion Method AQ4500 also reduces errors due to color absorption by using two photo detectors. In addition to the nephelometric, 90-degree detector, the AQ4500 turbidimeter has a transmitted (180-degree) light detector 46. The light that reaches the transmitted detector is used as a reference beam against the nephelometric scattered light beam. This allows for color compensation due to absorption.

Online Turbidity Water Clarity Sensor 20m Depth KTU310

The Orion Method AQ4500 uses ratiometric, nephelometric technology to measure turbidity.

To remain compliant with the EPA, the Orion Method AQ4500 has a limited range of 0.06-40 NTU. If a sample reads over this limit, it should be diluted to below 40 NTU. The new measurement can then be multiplied by the dilution factor to determine the turbidity of the original sample. While the manual for this instrument claims that it can be used from 0-4000 NTU, the approved version of this method limits readings to 40 NTU. It should be noted that just because an instrument or method is approved by the EPA does not mean that it is compliant with EPA Method 180.1. The Thermo Orion AQ4500 turbidimeter is EPA-approved for turbidities between 0.06-40 NTU, but because it uses an LED and not a tungsten filament lamp, it is not compliant with EPA Method 180.1.


Product Tags:

Online Turbidity Water Clarity Sensor

      

20m depth Online Turbidity Sensor

      
Quality Online Turbidity Water Clarity Sensor 20m Depth KTU310 for sale

Online Turbidity Water Clarity Sensor 20m Depth KTU310 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)