5ppm Infrared SF6 Air Purity Sensor 0-90%RH

Brand Name : Kacise

Model Number : KSS532

Place of Origin : shanxi xi'an

MOQ : 1

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 Pieces per Week

Delivery Time : 5 work days

Packaging Details : each unit has indicidual box and all boxes are packed in standard packages or customers requests available

Storage Temperature : -20-80℃

Operating Temperature : -20-60℃

Operating Humidity : 0-90%RH

Work Pressure : 0.8-1.2 atm

Supply Voltage : 12V

Maximum Operating Current : 120mA

Detection Range (customizable). : 1500ppm

Resolution : 5ppm

Measurement Accuracy : ± 30ppm or ±5% true value is the greater

T90 Pipeline Type of Pump suction : 5S

T90 Pipeline Type of Diffusion : 30S

Repeatability of Zero : Less than ±50

Repeatability of Range : Less than ±5%.

Life Span : 5-10 years

Contact Now

KSS532 Infrared SF6 Purity Sensor

1. Overview

KSS532 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.6um. KSS532 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize space dual optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS532 has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; Built-in temperature sensor for temperature compensation; At the same time, it has UART and 485 output, which is convenient for customers to apply various applications.

2. Technical parameters

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20 60 °C
Operating Humidity HA 0 90 % RH
Work Pressure PA 0.8 1.2 atm
Supply Voltage Vs 11 12 30 V
Maximum Operating Current Iavg 100 120 150 mA
Detection Range (customizable). Ra 1500 ppm
Resolution Resolution 5 ppm
Measurement Accuracy Acurracy ± 30 or ±5% true value is the greater %vol
T90 Pipeline Type Pump suction 5 second
Diffusion 30 second
Repeatability Zero Less than ±50 ppm
Range Less than ±5%.
Life Span 5 10 year

3. Structural Dimension Drawing

Unit: mm

5ppm Infrared SF6 Air Purity Sensor 0-90%RH

KSS532 block diagram (diffusion and pumping compatible).

Pump suction type: length * width * height: 61mm * 40mm * 32mm

Diffusion type: length * width * height: 61mm * 40mm * 18mm

4. Installation instructions

The sensor mounting positioning hole is installed according to the structural dimension drawing, and the aperture is 3.2mm.

The wiring socket spacing is 2.54 m m.

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, not more than 3 months is recommended.

Do not use the sensor for a long time in an environment with a high density of dust.

Please use the sensor within the range of the sensor's power supply.

6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Measure the gas

3) Sensor range

For example, SW320D, SF6, 0-5000 ppm

7. Order Information

Order information sheet
KSS532 KSS532 CO2 concentration sensor
xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KSS532 -2000 -S -38400 -Modbus-RTU

8. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride


Product Tags:

SF6 Air Purity Sensor

      

5ppm SF6 Purity Sensor

      

90%RH SF6 Purity Sensor

      
Quality 5ppm Infrared SF6 Air Purity Sensor 0-90%RH for sale

5ppm Infrared SF6 Air Purity Sensor 0-90%RH Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)