Brand Name : Kacise

Model Number : KSS525

Place of Origin : shanxi xi'an

MOQ : 1

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 Pieces per Week

Delivery Time : 5 work days

Packaging Details : each unit has indicidual box and all boxes are packed in standard packages or customers requests available

Storage Temperature : -20-80℃

Operating Temperature : -20-60℃

Work Pressure : 0.8-1.2 atm

Operating Humidity : 0-90%RH

Supply Voltage : 12V

Maximum operating Current : 120-150mA

Range (customizable) : 100ppm

Measurement accuracy : ± 0.5ppm or ±2% true value is the greater ppm

T90 of Pump-suction : 5S

Repeatability of 50%F.S. : <+2%.

Life Span : 10 years

Contact Now

KSS525 Infrared SF6 Gas Sensor Module

1. overview

KSS525 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.6um. KSS525 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize spatial dual-optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS525 has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; Built-in temperature sensor for temperature compensation; At the same time, it has UART, 485 output and analog voltage output, which is convenient for customers to various applications.

KSS525 physical image

2. Technical parameters

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20 60 °C
Operating Humidity HA 0 90 % RH
Work Pressure PA 0.8 1.2 atm
Supply Voltage Vs 9 12 24 V
Maximum operating current Iavg 100 120 150 mA
Range (customizable) 100 ppm
Measurement accuracy Acurracy 0.5ppm or ±2% true value is the greater %vol
T90 Pump suction 5 second
Repeatability 50%F.S. <+2%.
Life Span 10 year

3. Structural dimension drawing

100ppm Sulfur Hexafluoride Sensor SF6 Sensor Module High Efficiency

100ppm Sulfur Hexafluoride Sensor SF6 Sensor Module High Efficiency

4.Installation instructions

The sensor is mounted with a positioning hole spacing of 64 mm and an aperture of 3 mm

The wiring socket spacing is 2.54 m m

5.Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required if automatic calibration is turned on for long-term operation

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Measure the gas

3) Sensor range

For example, SW521R200, SF6, 0-100 ppm

7. Release Notes

In order to facilitate the better use of this product, V1.2 updates the calculation method of returning concentration value in the 4.3.2 MODBUS RTU protocol and the command description of reading concentration value after changing the address.

8. Ordering Information

Order information sheet
KSS525 KSS525 infrared SF6 gas sensor module
xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KSS525 -2000 -S -38400 -Modbus-RTU

Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride


Product Tags:

100ppm Sulfur Hexafluoride Sensor

      

100ppm SF6 Sensor Module

      

Sulfur Hexafluoride SF6 Sensor Module

      
Quality 100ppm Sulfur Hexafluoride Sensor SF6 Sensor Module High Efficiency for sale

100ppm Sulfur Hexafluoride Sensor SF6 Sensor Module High Efficiency Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)